Search Results For:
industrial parker piston pump
(90 Items)-
Parker Piston Pump PV016R1K1T1NFHS PV016R1K1T1NFR1 PV016R1K1T1NFWS PV016R1K1T1NMM1 PV016R1K1T1NMMC
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity -
Parker Piston Pump PV180L1K1DFNUPMX5899 PV180L1K1DFNUPM4445X5899 PV180L1K1L1NUPR PV180L1K1L1NUPR4445
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity -
Parker Piston Pump PAVC100B32L46B3A22PAVC100B32L46B3C22PAVC100B32L46B3CP22PAVC100B32L46B3P22
Used in conjunction with fluid types: Standard Hydraulic Fluids, Phosphate-ester, Water-Glycol Weight: 40 to 110 lb, 18 to 50 kg Control method: Pressure Limiter, Load Sense, Torque Limiting Maximum displacement: 6.1 inch3/rev, 100 cm3/rev Radial load capacity: 230 lb, 104 kg Direct drive capability: Yes Including filters: No Maximum flow rate: 260 L/min, 69 gal/min Medium: Hydraulic Fluids Installation plan: SAE to configure: Tandem, Single, Multiple Port type: Straight -
Parker Piston Pump PAVC1003R45HM22
Used in conjunction with fluid types: Standard Hydraulic Fluids, Phosphate-ester, Water-Glycol Weight: 40 to 110 lb, 18 to 50 kg Control method: Pressure Limiter, Load Sense, Torque Limiting Maximum displacement: 6.1 inch3/rev, 100 cm3/rev Radial load capacity: 230 lb, 104 kg Direct drive capability: Yes Including filters: No Maximum flow rate: 260 L/min, 69 gal/min Medium: Hydraulic Fluids Installation plan: SAE to configure: Tandem, Single, Multiple Port type: Straight -
Parker Piston Pump PV270R1K1L1NTLC
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity -
Parker Piston Pump PV270R1K1T1NUPG
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity -
Parker Piston Pump PV270R1D3T1WFFZ PV270R1E1B4NFRP PV270R1E1E3NFPR PV270R1E1T1NFP
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity -
Parker Piston Pump PV032R1K1T1NFF1 PV032R1K1T1NFHS PV032R1K1T1NFR1 PV032R1K1T1NFRC PV032R1K1T1NFWS
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity -
Parker Piston Pump PV040R1K1T1NMM1 PV040R1K1T1NMMC PV040R1K1T1NMRC PV040R1K1T1PMMC PV040R1K1T1V001
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity