Parker Piston Pump PAVC100D32L42A22
Used in conjunction with fluid types: Standard Hydraulic Fluids, Phosphate-ester, Water-Glycol Weight: 40 to 110 lb, 18 to 50 kg Control method: Pressure Limiter, Load Sense, Torque Limiting Maximum displacement: 6.1 inch3/rev, 100 cm3/rev Radial load capacity: 230 lb, 104 kg Direct drive capability: Yes Including filters: No Maximum flow rate: 260 L/min, 69 gal/min Medium: Hydraulic Fluids Installation plan: SAE to configure: Tandem, Single, Multiple Port type: Straight
Parker Piston Pump PAVC1009B2R46C3A22
Used in conjunction with fluid types: Standard Hydraulic Fluids, Phosphate-ester, Water-Glycol Weight: 40 to 110 lb, 18 to 50 kg Control method: Pressure Limiter, Load Sense, Torque Limiting Maximum displacement: 6.1 inch3/rev, 100 cm3/rev Radial load capacity: 230 lb, 104 kg Direct drive capability: Yes Including filters: No Maximum flow rate: 260 L/min, 69 gal/min Medium: Hydraulic Fluids Installation plan: SAE to configure: Tandem, Single, Multiple Port type: Straight
Parker Piston Pump PAVC1002R46B3P22
Used in conjunction with fluid types: Standard Hydraulic Fluids, Phosphate-ester, Water-Glycol Weight: 40 to 110 lb, 18 to 50 kg Control method: Pressure Limiter, Load Sense, Torque Limiting Maximum displacement: 6.1 inch3/rev, 100 cm3/rev Radial load capacity: 230 lb, 104 kg Direct drive capability: Yes Including filters: No Maximum flow rate: 260 L/min, 69 gal/min Medium: Hydraulic Fluids Installation plan: SAE to configure: Tandem, Single, Multiple Port type: Straight
Parker Piston Pump PAVC33B2L4A26
Used in conjunction with fluid types: Standard Hydraulic Fluids, Phosphate-ester, Water-Glycol Weight: 40 to 110 lb, 18 to 50 kg Control method: Pressure Limiter, Load Sense, Torque Limiting Maximum displacement: 6.1 inch3/rev, 100 cm3/rev Radial load capacity: 230 lb, 104 kg Direct drive capability: Yes Including filters: No Maximum flow rate: 260 L/min, 69 gal/min Medium: Hydraulic Fluids Installation plan: SAE to configure: Tandem, Single, Multiple Port type: Straight
Parker Piston Pump PAVC33BR4C26
Used in conjunction with fluid types: Standard Hydraulic Fluids, Phosphate-ester, Water-Glycol Weight: 40 to 110 lb, 18 to 50 kg Control method: Pressure Limiter, Load Sense, Torque Limiting Maximum displacement: 6.1 inch3/rev, 100 cm3/rev Radial load capacity: 230 lb, 104 kg Direct drive capability: Yes Including filters: No Maximum flow rate: 260 L/min, 69 gal/min Medium: Hydraulic Fluids Installation plan: SAE to configure: Tandem, Single, Multiple Port type: Straight
Parker Piston Pump PV180R1K1L1NULA
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity
Parker Piston Pump PV270R1K1T1NFT1
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity
Parker Piston Pump PV180R1L1T1NFWS
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity
Parker Piston Pump PV270R1K1T1N2LC
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity
Parker Piston Pump PV016R1K1T1NFHS PV016R1K1T1NFR1 PV016R1K1T1NFWS PV016R1K1T1NMM1 PV016R1K1T1NMMC
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity
Parker Piston Pump PV180L1K1DFNUPMX5899 PV180L1K1DFNUPM4445X5899 PV180L1K1L1NUPR PV180L1K1L1NUPR4445
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity
Parker Piston Pump PAVC100B32L46B3A22PAVC100B32L46B3C22PAVC100B32L46B3CP22PAVC100B32L46B3P22
Used in conjunction with fluid types: Standard Hydraulic Fluids, Phosphate-ester, Water-Glycol Weight: 40 to 110 lb, 18 to 50 kg Control method: Pressure Limiter, Load Sense, Torque Limiting Maximum displacement: 6.1 inch3/rev, 100 cm3/rev Radial load capacity: 230 lb, 104 kg Direct drive capability: Yes Including filters: No Maximum flow rate: 260 L/min, 69 gal/min Medium: Hydraulic Fluids Installation plan: SAE to configure: Tandem, Single, Multiple Port type: Straight
Parker Piston Pump PAVC1003R45HM22
Used in conjunction with fluid types: Standard Hydraulic Fluids, Phosphate-ester, Water-Glycol Weight: 40 to 110 lb, 18 to 50 kg Control method: Pressure Limiter, Load Sense, Torque Limiting Maximum displacement: 6.1 inch3/rev, 100 cm3/rev Radial load capacity: 230 lb, 104 kg Direct drive capability: Yes Including filters: No Maximum flow rate: 260 L/min, 69 gal/min Medium: Hydraulic Fluids Installation plan: SAE to configure: Tandem, Single, Multiple Port type: Straight
Parker Piston Pump PV270R1K1L1NTLC
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity
Parker Piston Pump PV270R1K1T1NUPG
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity
Parker Piston Pump PV270R1D3T1WFFZ PV270R1E1B4NFRP PV270R1E1E3NFPR PV270R1E1T1NFP
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity
Parker Piston Pump PV032R1K1T1NFF1 PV032R1K1T1NFHS PV032R1K1T1NFR1 PV032R1K1T1NFRC PV032R1K1T1NFWS
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity
Parker Piston Pump PV040R1K1T1NMM1 PV040R1K1T1NMMC PV040R1K1T1NMRC PV040R1K1T1PMMC PV040R1K1T1V001
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity
Parker Piston Pump PV140R1K4C1NFPR PV140R1K4C1NUPR PV140R1K4C1NUPR4445
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity
Parker Piston Pump PV270R1L1B1NFR2+ PVAC1PCMN PV270R1L1M3NF PV PV270R1L1T1N001X5899 PV270R1L1T1WMFC
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity
Parker Piston Pump PAVC65R42H13
Used in conjunction with fluid types: Standard Hydraulic Fluids, Phosphate-ester, Water-Glycol Weight: 40 to 110 lb, 18 to 50 kg Control method: Pressure Limiter, Load Sense, Torque Limiting Maximum displacement: 6.1 inch3/rev, 100 cm3/rev Radial load capacity: 230 lb, 104 kg Direct drive capability: Yes Including filters: No Maximum flow rate: 260 L/min, 69 gal/min Medium: Hydraulic Fluids Installation plan: SAE to configure: Tandem, Single, Multiple Port type: Straight
Scan to add on WeChat