Servo Valve
Parker Piston Pump PAVC1009BR4AP22PAVC1009BR4M22PAVC1009BR4P22PAVC1009C2L46C3P22-
Used in conjunction with fluid types: Standard Hydraulic Fluids, Phosphate-ester, Water-Glycol Weight: 40 to 110 lb, 18 to 50 kg Control method: Pressure Limiter, Load Sense, Torque Limiting Maximum displacement: 6.1 inch3/rev, 100 cm3/rev Radial load capacity: 230 lb, 104 kg Direct drive capability: Yes Including filters: No Maximum flow rate: 260 L/min, 69 gal/min Medium: Hydraulic Fluids Installation plan: SAE to configure: Tandem, Single, Multiple Port type: Straight
Parker Piston Pump PAVC100B32L46B3A22PAVC100B32L46B3C22PAVC100B32L46B3CP22PAVC100B32L46B3P22
Used in conjunction with fluid types: Standard Hydraulic Fluids, Phosphate-ester, Water-Glycol Weight: 40 to 110 lb, 18 to 50 kg Control method: Pressure Limiter, Load Sense, Torque Limiting Maximum displacement: 6.1 inch3/rev, 100 cm3/rev Radial load capacity: 230 lb, 104 kg Direct drive capability: Yes Including filters: No Maximum flow rate: 260 L/min, 69 gal/min Medium: Hydraulic Fluids Installation plan: SAE to configure: Tandem, Single, Multiple Port type: Straight
Parker Piston Pump PAVC33B2L4AP26PAVC33B2L4C26PAVC33B2R4226PAVC33B2R426
Used in conjunction with fluid types: Standard Hydraulic Fluids, Phosphate-ester, Water-Glycol Weight: 40 to 110 lb, 18 to 50 kg Control method: Pressure Limiter, Load Sense, Torque Limiting Maximum displacement: 6.1 inch3/rev, 100 cm3/rev Radial load capacity: 230 lb, 104 kg Direct drive capability: Yes Including filters: No Maximum flow rate: 260 L/min, 69 gal/min Medium: Hydraulic Fluids Installation plan: SAE to configure: Tandem, Single, Multiple Port type: Straight
ConstantVoltage Piston Pump P1100PA02SRS5AL0TS1000000
Maximum vacuum flow rate: n/a working pressure: 280 bar, 4000 psi Technology: Hydraulics Current Speed: 250 L/min, 66 gal/min Displacement: 140 cm3/rev, 8.5 inch3/rev Valve body material: cast iron Drainage options: Yes Including supply pump: No Circuit path: normally open Configuration: Single/Serial/Multiple, Tandem, Multiple Control method: pressure limiter | load sensitive | electronic control | unloading | proportional | fan drive, Load Sense, Electronic Control,
HydraulicPressure Piston Pump P1140PSO2SRS5BC00S0000000
Maximum vacuum flow rate: n/a working pressure: 280 bar, 4000 psi Technology: Hydraulics Current Speed: 250 L/min, 66 gal/min Displacement: 140 cm3/rev, 8.5 inch3/rev Valve body material: cast iron Drainage options: Yes Including supply pump: No Circuit path: normally open Configuration: Single/Serial/Multiple, Tandem, Multiple Control method: pressure limiter | load sensitive | electronic control | unloading | proportional | fan drive, Load Sense, Electronic Control,
Variable Piston Pump PD045PB04SRS5AC00R100PB00
Maximum vacuum flow rate: n/a working pressure: 280 bar, 4000 psi Technology: Hydraulics Current Speed: 250 L/min, 66 gal/min Displacement: 140 cm3/rev, 8.5 inch3/rev Valve body material: cast iron Drainage options: Yes Including supply pump: No Circuit path: normally open Configuration: Single/Serial/Multiple, Tandem, Multiple Control method: pressure limiter | load sensitive | electronic control | unloading | proportional | fan drive, Load Sense, Electronic Control,
Parker Piston Pump PV270R1L1B1NFR2+ PVAC1PCMN PV270R1L1M3NF PV PV270R1L1T1N001X5899 PV270R1L1T1WMFC
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity
Parker Piston Pump PV040R1K1T1NMM1 PV040R1K1T1NMMC PV040R1K1T1NMRC PV040R1K1T1PMMC PV040R1K1T1V001
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity
Parker Piston Pump PV140R9K1T1WSCCK0072 PV140R9K4T1NFFPK0088 PV140R9K4T1NZCBK0154 PV140R9K4T1WFRPX5918
General Information Fluid recommendations Premium quality hydraulic mineral fluid is recommended, like HLP oils to DIN 51524 (part 2 & 3) or ISO6743/4 (HM & HV). Brugger-value recommended to be 30 N/mm2 minimum for general application and 50 N/ mm2 for heily loaded hydraulic equipment and fast cycling machines and/or high dynamic loads, measured in accordance with DIN 51 347-2. See also Document MSG30-3248/UK Parker Hydraulic Fluids. Viscosity The normal operating viscosity